Description
Technical Details: SZ-7524T2
1. Control Mechanism
-
Control Type: PID (Proportional-Integral-Derivative) or On-Off (configurable). The “T2” typically indicates a dual-probe or advanced timing version of the standard 7524.
-
Input Type: Dual NTC Sensors (1 for Room Temperature, 1 for Evaporator/Coil Temperature).
-
Output Configuration: Features three independent relays:
-
Compressor: Usually 8(3)A or 20A depending on the specific build.
-
Defrost: 8(3)A (Heater control).
-
Evaporator Fan: 8(3)A
-
2. Operational Range & Precision
-
Temperature Range: -50C to +50C (Standard for refrigeration/freezing).
-
Accuracy: \pm 1C.
-
Resolution: 0.1C (for precise readout) or 1C settable.
-
Power Supply: Standard 230V AC pm 15% (50/60 Hz); also available in DC variants.
3. Physical & Safety Specifications
-
Display: 3-Digit, 0.56″ High-brightness Red LED display.
-
Protection: Built-in Compressor Protection Algorithm (prevents short-cycling).
-
Ingress Protection: IP65 rated front panel (dust-tight and protected against water jets).
-
Panel Cutout: 71times 29 mm (Industry standard “Small” format).